Work

Mitigation of stomach dehiscence risk during gastrostomy tube changes - a retrospective analysis of patient outcomes.

Publique Deposited

MLA citation style (9th ed.)

Smith, David A, and Blocher-Smith, Ethan Charles OMS III. Mitigation of Stomach Dehiscence Risk During Gastrostomy Tube Changes - a Retrospective Analysis of Patient Outcomes. . 4120. mushare.marian.edu/concern/generic_works/de1022c7-38c2-46fd-8efc-212dd011a680?locale=fr.

APA citation style (7th ed.)

S. D. A, & B. E. C. O. Iii. (4120). Mitigation of stomach dehiscence risk during gastrostomy tube changes - a retrospective analysis of patient outcomes. https://mushare.marian.edu/concern/generic_works/de1022c7-38c2-46fd-8efc-212dd011a680?locale=fr

Chicago citation style (CMOS 17, author-date)

Smith, David A, and Blocher-Smith, Ethan Charles OMS III. Mitigation of Stomach Dehiscence Risk During Gastrostomy Tube Changes - a Retrospective Analysis of Patient Outcomes. 4120. https://mushare.marian.edu/concern/generic_works/de1022c7-38c2-46fd-8efc-212dd011a680?locale=fr.

Note: These citations are programmatically generated and may be incomplete.

INTRODUCTION: Stomach dehiscence from the abdominal wall is a serious and potentially life-threatening complication of gastrostomy tube changes. This retrospective study evaluates gastric aspiration as an inexpensive and safe alternative to endoscopic or radiographic confirmation. METHODS: From August 1998 to June 2016, 682 patients (301 female, 381 male) underwent 1713 gastrostomy tube changes in the medical setting, with an average age of 7.59years and an average site age of 3.43years. The most common diagnoses were GERD (304), aspiration (168), and failure to thrive (143). RESULTS: All newly inserted tubes were aspirated to visually inspect for gastric fluid. This procedure as a confirmatory test for intragastric placement was found to have a positive predictive value of 99.5% and negative predictive value of 77.8%, with a sensitivity of 99.8% and specificity of 63.6%. In cases with successful aspiration of gastric fluid, 75.5% of changes resulted in no complications, with intraperitoneal insertion or leak in only 0.48% of cases. CONCLUSIONS: Positive gastric aspirate is a strong predictor of proper G-tube placement with high sensitivity, eliminating the requirement of specialized equipment and the cost associated with endoscopic or radiographic guidance, and has a comparable or superior risk profile. LEVELS OF EVIDENCE: Study of diagnostic test level II.

Creator
Language
Identifier
Mot-clé
Date created
Related URL
Resource type
Source
  • mucom_spr_3

  • Journal of Pediatric Surgery

Rights statement

Relations

Relations

Dans Collection:

Contenu